Cabin page
The cabin page opens when you click a cabin in the list. The header has the name and serial number and the buttons Logs (the cabin's exchange with the server, in a separate window, see Telemetry and log), Edit (name, address, tags) and Save (save mode settings).
Tabs: Configuration, Statistics, Telemetry, Bookings (plus Info on a phone).
Cabin details
On the left — the cabin type photo, serial number, region, owner, installation date, address, connection and current statuses.
Alerts
If something is wrong with the cabin, a red block appears below the details. An alert stays while the problem lasts; the time is when it appeared. The interface shows alert texts in Russian:
| Line | Meaning | What to do |
|---|---|---|
| нет связи (offline) | the cabin has not been online for more than 5 minutes | check the cabin power and the site Wi-Fi, see Troubleshooting |
| отказ датчика веса (load cell failure) | one of the floor load cells returns no data | check the cell connector and wire; the cabin keeps working on the healthy one |
| NVS не пишется (NVS not writable) | the board cannot write data to its memory | contact support |
| откат прошивки после обновления (firmware rollback) | a new firmware version was not confirmed and the cabin went back to the previous one | the cabin runs the previous version; tell support |
| аварийный режим прошивки (firmware safe mode) | after several failures in a row the cabin runs a safe configuration | see Safe mode |
In safe mode the same block names the mode and the disabled firmware tasks, for example scales,mode — the scales and the mode logic.
The same block has lines about visits when there is something to say:
| Line | Meaning | What to do |
|---|---|---|
| Ручное вмешательство: … (manual override, yellow) | the entry sign, the brightness or the weight was set by a command from the dashboard (Cabin controls); the weight override holds until Off on the scale row, and while it is on the cabin does not count real visits (firmware ≥1.0.291). The sign and the brightness and holds until the cabin's mode changes: the sign is released by entry_auto or a mode change, the brightness by a mode change. The cabin reports it in its status (entry_manual, light_manual, firmware ≥1.0.282) | |
| Потеряно визитов: N (visits lost) | the cabin failed to keep N visits over its life: it was offline for long, the visit memory overflowed and there is no SD card (or the board memory cannot be written). A growing number also sends a Telegram message | find out why the cabin stays offline for long; put in an SD card |
| Визитов ждут на карте памяти: N (visits waiting on the SD card) | the cabin was offline for long, the visit memory overflowed and the visits went to the card. They are not lost: the cabin is sending them, the number goes down | nothing; if the number does not go down while online, tell support |
Configuration
Live controls
The Cabin controls (live) block controls the cabin right now. The values are not saved to the settings: at the next mode change the cabin returns to its levels.
| Control | What it does |
|---|---|
| status line | mode (mode) and how many seconds ago the cabin status arrived; the floor weight is in the State card (Read from cabin) |
| Light in the cabin | light brightness, % |
| Fan | fan speed, % |
| Lamp: Top / Front | which lamp is lit — top or front (one of the two) |
| Scale: Person / Empty / Off | checking a cabin without a person: Person — the cabin considers someone inside (the cabin's presence threshold + 10 kg; 70 kg when the threshold is unknown), Empty — considers it empty, Off — back to the real scales |
| Entry sign | the entrance sign: Set free, Set busy, Off — both lamps off; a manual state holds until the cabin's next mode change. Auto — back to automatic now: the sign follows the current mode (firmware ≥1.0.285), the manual-override badge goes out |
- A slider sends the command 0.4 seconds after you release it. Until the cabin confirms the value, a waiting mark is shown next to it.
- If someone turns the light or fan knob in the cabin, the slider in the interface moves by itself.
After a check — Off
Person / Empty replaces the scale readings. Do not leave it on: the cabin stops noticing real people and visits are not recorded. Press Off when the check is done.
Modes
Three cards — the levels the cabin applies by itself in each mode:
| Card | Mode | Fields |
|---|---|---|
| Operational | Work — someone inside | LED brightness level, Fan ventilation level |
| Standby mode | Wait — empty, working hours | brightness, ventilation, Ventilation interval — how often to air the empty cabin, Duration time — how long the airing lasts |
| Sleep mode | Sleep — empty, outside working hours | same as Standby |
Setup
| Field | What it sets |
|---|---|
| Work day start time, Work day end time | the working day: inside it an empty cabin is in Wait, outside — Sleep. The start is before the end, within one day |
| Weekends | weekend days — Sleep all day |
| Time zone | the cabin's time zone: the working day is counted by it |
| Fan range (0-255) | the fan working range — for the motor model: the minimum at which it spins, and the maximum |
| Fan slow mode | smooth fan ramp-up |
| Reboot cabin → Reboot | restart the cabin; it is back online in about half a minute |
| Update Firmware → Update (provider only, when the catalog has a newer version) | update the firmware over the air. The button gives way to a bar and a stage: “Sent” → “Downloading N %” (the cabin reports progress in steps of 10) → “Installing” (signature check, flashing) → “Rebooting” → “Updated to X”. If the cabin rolled back or came back with the same version, the reason is shown under the bar; no change for 3 minutes — “No response”, check the cabin log |
Saving settings
Mode settings and Setup show what the cabin reported last: the tab opens at once, even if the cabin is offline right now. After editing, press Save in the page header:
- the cabin must be online;
- only what you changed is sent, as one command — the cabin applies all or nothing;
- the settings are stored in the cabin itself and work without a server link.
Site Wi-Fi
A company administrator sees the More settings section below with the cabin's Wi-Fi: --wifi-networks is the list of networks the cabin may join, up to five, typed as name:password,name:password. The cabin shows only the names, never the passwords, so the list is typed again in full. When the office network or its password has changed:
- type the whole list with the new network or password, press Apply and confirm the question;
- the cabin uses the new list at once (firmware 1.0.314 and newer; older firmware after Reboot cabin → Reboot). It keeps its current network until that one disappears.
A mistake is not fatal: if the cabin does not come back online within 5 minutes with the new values, it returns the previous ones by itself and restarts. Other employees do not see this section.
Other tabs
- Statistics — the cabin's visits, see Statistics.
- Telemetry — the board state: signal, memory, scales, restarts, see Telemetry and log.
- Bookings — the booking schedule and calendar binding, see Bookings.
The ? icon next to the tabs opens the guide section about the open tab.