Skip to content

Cabin page ​

The cabin page opens when you click a cabin in the list. The header has the name and serial number and the buttons Logs (the cabin's exchange with the server, in a separate window, see Telemetry and log), Edit (name, address, tags) and Save (save mode settings).

Tabs: Configuration, Statistics, Telemetry, Bookings (plus Info on a phone).

Cabin details ​

On the left — the cabin type photo, serial number, region, owner, installation date, address, connection and current statuses.

Alerts ​

If something is wrong with the cabin, a red block appears below the details. An alert stays while the problem lasts; the time is when it appeared. The interface shows alert texts in Russian:

LineMeaningWhat to do
нет связи (offline)the cabin has not been online for more than 5 minutescheck the cabin power and the site Wi-Fi, see Troubleshooting
отказ датчика веса (load cell failure)one of the floor load cells returns no datacheck the cell connector and wire; the cabin keeps working on the healthy one
NVS не пишется (NVS not writable)the board cannot write data to its memorycontact support
откат прошивки после обновления (firmware rollback)a new firmware version was not confirmed and the cabin went back to the previous onethe cabin runs the previous version; tell support
аварийный режим прошивки (firmware safe mode)after several failures in a row the cabin runs a safe configurationsee Safe mode

In safe mode the same block names the mode and the disabled firmware tasks, for example scales,mode — the scales and the mode logic.

The same block has lines about visits when there is something to say:

LineMeaningWhat to do
Ручное вмешательство: … (manual override, yellow)the entry sign, the brightness or the weight was set by a command from the dashboard (Cabin controls); the weight override holds until Off on the scale row, and while it is on the cabin does not count real visits (firmware ≥1.0.291). The sign and the brightness and holds until the cabin's mode changes: the sign is released by entry_auto or a mode change, the brightness by a mode change. The cabin reports it in its status (entry_manual, light_manual, firmware ≥1.0.282)
Потеряно визитов: N (visits lost)the cabin failed to keep N visits over its life: it was offline for long, the visit memory overflowed and there is no SD card (or the board memory cannot be written). A growing number also sends a Telegram messagefind out why the cabin stays offline for long; put in an SD card
Визитов ждут на карте памяти: N (visits waiting on the SD card)the cabin was offline for long, the visit memory overflowed and the visits went to the card. They are not lost: the cabin is sending them, the number goes downnothing; if the number does not go down while online, tell support

Configuration ​

Live controls ​

The Cabin controls (live) block controls the cabin right now. The values are not saved to the settings: at the next mode change the cabin returns to its levels.

ControlWhat it does
status linemode (mode) and how many seconds ago the cabin status arrived; the floor weight is in the State card (Read from cabin)
Light in the cabinlight brightness, %
Fanfan speed, %
Lamp: Top / Frontwhich lamp is lit — top or front (one of the two)
Scale: Person / Empty / Offchecking a cabin without a person: Person — the cabin considers someone inside (the cabin's presence threshold + 10 kg; 70 kg when the threshold is unknown), Empty — considers it empty, Off — back to the real scales
Entry signthe entrance sign: Set free, Set busy, Off — both lamps off; a manual state holds until the cabin's next mode change. Auto — back to automatic now: the sign follows the current mode (firmware ≥1.0.285), the manual-override badge goes out
  • A slider sends the command 0.4 seconds after you release it. Until the cabin confirms the value, a waiting mark is shown next to it.
  • If someone turns the light or fan knob in the cabin, the slider in the interface moves by itself.

After a check — Off

Person / Empty replaces the scale readings. Do not leave it on: the cabin stops noticing real people and visits are not recorded. Press Off when the check is done.

Modes ​

Three cards — the levels the cabin applies by itself in each mode:

CardModeFields
OperationalWork — someone insideLED brightness level, Fan ventilation level
Standby modeWait — empty, working hoursbrightness, ventilation, Ventilation interval — how often to air the empty cabin, Duration time — how long the airing lasts
Sleep modeSleep — empty, outside working hourssame as Standby

Setup ​

FieldWhat it sets
Work day start time, Work day end timethe working day: inside it an empty cabin is in Wait, outside — Sleep. The start is before the end, within one day
Weekendsweekend days — Sleep all day
Time zonethe cabin's time zone: the working day is counted by it
Fan range (0-255)the fan working range — for the motor model: the minimum at which it spins, and the maximum
Fan slow modesmooth fan ramp-up
Reboot cabin → Rebootrestart the cabin; it is back online in about half a minute
Update Firmware → Update (provider only, when the catalog has a newer version)update the firmware over the air. The button gives way to a bar and a stage: “Sent” → “Downloading N %” (the cabin reports progress in steps of 10) → “Installing” (signature check, flashing) → “Rebooting” → “Updated to X”. If the cabin rolled back or came back with the same version, the reason is shown under the bar; no change for 3 minutes — “No response”, check the cabin log

Saving settings ​

Mode settings and Setup show what the cabin reported last: the tab opens at once, even if the cabin is offline right now. After editing, press Save in the page header:

  • the cabin must be online;
  • only what you changed is sent, as one command — the cabin applies all or nothing;
  • the settings are stored in the cabin itself and work without a server link.

Site Wi-Fi ​

A company administrator sees the More settings section below with the cabin's Wi-Fi: --wifi-networks is the list of networks the cabin may join, up to five, typed as name:password,name:password. The cabin shows only the names, never the passwords, so the list is typed again in full. When the office network or its password has changed:

  1. type the whole list with the new network or password, press Apply and confirm the question;
  2. the cabin uses the new list at once (firmware 1.0.314 and newer; older firmware after Reboot cabin → Reboot). It keeps its current network until that one disappears.

A mistake is not fatal: if the cabin does not come back online within 5 minutes with the new values, it returns the previous ones by itself and restarts. Other employees do not see this section.

Other tabs ​

  • Statistics — the cabin's visits, see Statistics.
  • Telemetry — the board state: signal, memory, scales, restarts, see Telemetry and log.
  • Bookings — the booking schedule and calendar binding, see Bookings.

The ? icon next to the tabs opens the guide section about the open tab.

© Modular Acoustic Solutions · WorkBooth