Troubleshooting
Most questions are answered by three sources on the cabin page: the alerts block below the details, the Telemetry tab and the Logs window. If the cause is on the provider's side, press the support button in the header and include the cabin name, the time and the log lines.
The cabin is "Disconnected"
The cabin is not online with the server.
- Power. Are the light and sign in the cabin on? If not, check the circuit breaker and power supply.
- Site Wi-Fi. Is the access point working, do other devices near the cabin have internet?
- Wait a minute. After power or the network comes back, the cabin connects by itself, usually within 10–30 seconds.
- Signal. On the Telemetry tab look at the Wi-Fi signal chart before the drop: if the signal was below −75 dBm, the access point needs to be closer.
- The Wi-Fi network or password changed. The cabin connects to the network the provider set up. Tell support in advance about a network or password change.
The "нет связи" (offline) alert appears after 5 minutes offline and clears by itself when the cabin is back.
The cabin keeps dropping and coming back
- On the Telemetry tab compare Wi-Fi reconnects and MQTT reconnects.
- Both grow — the cabin loses the access point: weak signal, interference, router restarts. Check the router placement, remove metal obstacles, pick a less busy channel.
- Only MQTT grows — Wi-Fi is fine, the path to the server drops: site internet, network restrictions. Check the internet or tell support.
- In the Logs window → History find
MQTT reconnected (offline N s, …)lines — how long the drops lasted.
The cabin is always "busy"
| Check | Where | What to do |
|---|---|---|
| The Person scale check is on | cabin page → Cabin controls (live) → Scale | press Off |
| A booking is running (status Work Api) | Bookings tab | wait for the end or cancel the booking |
| The empty-cabin weight is not about zero | Telemetry → Weight, Scale zero | remove objects from the floor; if the floor is empty, ask support to zero the scales |
| The "отказ датчика веса" (load cell failure) alert | alerts block | check the load cell connector and wire |
| The sign was switched by hand | Cabin controls (live) → Entry sign | the sign follows the mode again at the next cabin state change |
The cabin does not notice a person
- Scale in the live controls is on Empty — press Off.
- The cabin page shows the "аварийный режим прошивки" (firmware safe mode) alert and the disabled tasks include
scalesormode— the scales and modes are off, see Safe mode. - On the Telemetry tab the Weight chart does not react to a person entering — check the load cells and their wires, tell support.
Wall knobs and buttons do not work
In an empty cabin (Sleep and Wait modes) the knobs and buttons are disabled — by design. They work when someone is inside or a booking is running. If the cabin is busy and the knobs do not respond, tell support.
The cabin is in the wrong mode for the schedule
- Check Setup on the cabin page: Work day start time, Work day end time, Weekends.
- Check Time zone: the working day is counted in the cabin's time zone, not the browser's.
- After editing press Save in the page header.
Settings are not saved
- The cabin must be online: the settings are stored in the cabin itself.
- If the cabin did not accept the values, it applies nothing — the Logs window shows a
SET_CONFIG rejected: …line with the reason. Fix the value and save again. - Live controls (Cabin controls) are not saved to the settings: at the next mode change the cabin returns to the levels from the mode cards.
The cabin restarts
- The Restarts card on the Telemetry tab — how many restarts in the range. One a day is the night preventive restart, that is normal.
- The cause of every restart is in the Logs window → History, the
MQTT connected after boot (…)line. Decoding — Restart causes. - Frequent
brownout— the board power: power supply, wiring, the load when the fan switches on. - Other frequent causes — send the log lines to support.
A booking cannot be created
- "slot is already taken" — the time overlaps another booking or a slot held after a person left (No-show timeout in the booking policy). Pick another time.
- A booking closed as no_show — nobody entered the cabin within the no-show time. Increase No-show timeout if people need more time to get there.
Bookings do not sync with the calendar
- On the Bookings tab → Calendar bindings the cabin has a calendar filled in: Calendar ID for Google or Cabin e-mail for Teams.
- Google: the cabin calendar is shared with the service account with permission to make changes to events.
- Teams: the application in Microsoft Entra has permissions to read users and write calendars, with admin consent.
- Events beyond Calendar look-ahead are not pulled — increase the horizon in the booking policy.
- A new calendar event appears in the interface within a minute, a booking from the interface appears in the calendar within seconds.
Details — Calendars: Google and Teams.
No visits in statistics
- Check that the Person / Empty scale check is not on — real visits are not recorded while the readings are replaced.
- The cabin was offline — visits are kept in the cabin and appear in statistics when the link returns.
- The cabin is in safe mode — visits are not counted, see Safe mode.